User Manual 1173.9511.02 ─ 12
If a correction table for frequency-dependent attenuation is active for the chosen con-
nector, then the table name and a button are displayed. Press the button to display the
table entries.
Remote command:
SOURce:EVDO:SIGN<i>:RFSettings:TX:EATTenuation
CONFigure:EVDO:SIGN<i>:RFSettings:EATTenuation
2.3.7.2
RF Input (RX)
Fig. 2-24: 1xEV-DO RF input (RX) settings
Routing
Selects the input path for the measured RF signal, i.e. the input connector and the RX
module to be used.
Depending on your hardware configuration there may be dependencies between both
parameters. Select the RF connector first. The "Converter" parameter offers only val-
ues compatible with the selected RF connector.
Remote command:
Depends on the scenario, see
chapter 2.5.6.1, "Signal Routing"
Example:
ROUTe:EVDO:SIGN<i>:SCENario:SCELl
External Attenuation
Defines the value of an external attenuation (or gain, if the value is negative) in the
input path. The power readings of the R&S
CMW are corrected by the external attenu-
ation value.
The external attenuation value is also used in the calculation of the maximum input
power that the R&S
CMW can measure.
If a correction table for frequency-dependent attenuation is active for the chosen con-
nector, then the table name and a button are displayed. Press the button to display the
table entries.
Remote command:
SOURce:EVDO:SIGN<i>:RFSettings:RX:EATTenuation
CONFigure:EVDO:SIGN<i>:RFSettings:EATTenuation
GUI Reference