![Rohde & Schwarz CMW-KE100 User Manual Download Page 852](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807852.webp)
CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
852
User Manual 1173.9511.02 ─ 12
<11_CFreqError>
Carrier frequency error
Range:
-5000 Hz to 5000 Hz
Default unit: Hz
<12_TransTimeErr> Transmit time error
Range:
-100 µs to 100 µs
Default unit: µs
<13_MSPow1M23>
MS power, measured with a filter bandwidth of 1.23 MHz.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<14_MSPowWide>
MS power, measured with a filter bandwidth of 8 MHz.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<15_WavQuality>
Waveform quality
Range:
0 to 1
<16_WavQuMaxP>
Waveform quality at maximum power.
Range:
0 to 1
<17_WavQuMinP>
Waveform quality at minimum power.
Range:
0 to 1
<18_OutOfTolCount> Out of tolerance result, i.e. percentage of measurement intervals
of the statistic count
(
CONFigure:CDMA:MEAS<i>:MEValuation:SCOunt:
MODulation
) exceeding the specified limits.
Range:
0 % to 100 %
Default unit: %
<19_CurStatCount> Number of evaluated valid slots in this segment.
Range:
0 to 1000
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.15.20,
V2.0.10: New parameter
<CurStatCount>
,
all
CALCulate:...
commands
Options:
R&S CMW-KM012
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:SEGMent<no>:ACP:CURRent?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:SEGMent<no>:ACP:AVERage?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:SEGMent<no>:ACP:MINimum?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:SEGMent<no>:ACP:SDEViation?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:SEGMent<no>:ACP:MAXimum?