![Rohde & Schwarz CMW-KE100 User Manual Download Page 109](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807109.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
109
User Manual 1173.9511.02 ─ 12
Results
For a detailed description of the results see
chapter 2.2.14.7, "RLP and IP Statistics"
Remote command:
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:RESet?
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:RACK?
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:NAK?
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:SUMMary?
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:PPPTotal?
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:DRATe?
SENSe:EVDO:SIGN<i>:RXQuality:IPSTatistics:STATe?
2.4 Programming
The following sections provide programming examples for the 1xEVDO signaling appli-
cation.
The examples contain SCPI commands supported by the R&S
CMW and the following
symbolic scripting commands:
●
// <comment>
:
Adds a comment to the source code of the script.
●
// <remark>
:
Adds a remark to the output of the script.
●
WHILE <query> <> <value>
:
Waits until the <query> returns a certain <value>, e.g. a specific state is reached.
●
WAITKEY <message>
:
Displays a dialog box with a <message> and wait until the box is closed by the
user.
See also: "Remote Control" in the R&S
CMW user manual
...........................................................................................109
................................................................................................ 121
2.4.1 General Configuration
The 1xEVDO signaling application is programmed as follows:
●
The application is controlled by SCPI commands with the following syn-
tax:
...:EVDO:SIGN:...
●
After a
*RST
, the forward signal is switched off.
–
To activate the forward signal use
SOURce:EVDO:SIGN:STATe ON
.
Query the cell state using
SOURce:EVDO:SIGN:STATe:ALL?
. The result
ON,ADJ
indicates that the forward signal is available.
–
To initiate a connection setup use
CALL:EVDO:SIGN:CSWitched:ACTion
CONNect
.
Programming
深圳德标仪器
135-1095-0799