![Rohde & Schwarz CMW-KE100 User Manual Download Page 760](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807760.webp)
CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
760
User Manual 1173.9511.02 ─ 12
Fig. 5-22: Multi evaluation configuration: limits
Limits
The limits can be configured via the following remote commands.
Remote command:
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:POWer
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:EVMagnitude
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:MERRor
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:PERRor
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:IQIMbalance
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:IQOFfset
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:CFERror
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:TTERror
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:WFQuality
CONFigure:CDMA:MEAS<i>:MEValuation:IQLCheck
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:CDP
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:CDE
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:CP
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:CPO
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:CTO
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:ACP:ABSolute
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:ACP[:RELative]
CONFigure:CDMA:MEAS<i>:MEValuation:LIMit:OBW
5.3.6 Generator Shortcut
This feature enables the user to start the GPRF generator and use GPRF related hot-
keys and softkeys within the measurement application. It improves the usability for non
signaling tests where the DUT's reaction on varying generator signals is measured.
The "Generator Shortcut" is only available in the "Standalone (Non Signaling)" mode.
Fig. 5-23: GPRF generator shortcut
As soon as a connection to the GPRF generator instance is established, two additional
softkeys with corresponding hotkey bars provide access to the generator configuration,
see
"ARB/List Mode, GPRF<i> Generator"
Use the appropriate softkey/hotkey combination to access the generator parameters.
GUI Reference