![Rohde & Schwarz CMW-KE100 User Manual Download Page 187](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807187.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
187
User Manual 1173.9511.02 ─ 12
Parameters:
<PDThreshold>
Range:
-31.5 dB to 0 dB
*RST:
-9 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:RLFoffset
<RLFOffset>
Delays the Reverse Traffic Data Channel and Reverse Rate Indicator Channel (RRI)
transmissions of the AT by an integer number of slots with respect to the system time-
aligned frame boundary.
Parameters:
<RLFOffset>
Range:
0 to 15
*RST:
8
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:ROMessages
<ROMessages>
Sets the 'Redirect' bit in the QuickConfig Message of the Overhead Messages Protocol
to '1'.
Parameters:
<ROMessages>
OFF | ON
*RST:
OFF
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
2.5.8.6
MAC Layer
The following parameters configure the MAC layer. All settings are valid for subtype
0/1 and for subtype 2 signals.
CONFigure:EVDO:SIGN<i>:LAYer:MAC:DRATe
............................................................... 188
CONFigure:EVDO:SIGN<i>:LAYer:MAC:SSEed?
..............................................................188
CONFigure:EVDO:SIGN<i>:LAYer:MAC:MPSequences
.................................................... 188
Command Reference