![Rohde & Schwarz CMW-KE100 User Manual Download Page 556](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807556.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
556
User Manual 1173.9511.02 ─ 12
Probe Increment
Sets the size of the power increment (PWR_STEP) between consecutive access
probes.
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:PINCrement
Probes per sequence
Sets the number of access probes (NUM_STEP) contained in a single access probe
sequence.
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:PPSequence
Sequences / Attempt / RSP
Maximum number of access probe sequences for an Access Channel or Enhanced
Access Channel response (MAX_RSP_SEQ).
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:SPATtempt:RSP
Sequences / Attempt / REQ
Maximum number of access probe sequences for an Access Channel or Enhanced
Access Channel request (MAX_REQ_SEQ).
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:SPATtempt:REQ
4.3.10 Messaging (SMS)
The "Messaging (SMS)" section configures parameters of the Short Message Service
(SMS). Refer also to standard 3GPP2 C.S0015-A.
For background information see
chapter 4.2.15, "Data Burst Message Applications"
Fig. 4-59: Messaging (SMS) settings overview
For parameter descriptions refer to the subsections.
...................................................................................... 557
...................................................................................... 560
GUI Reference