![Rohde & Schwarz CMW-KE100 User Manual Download Page 143](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807143.webp)
1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
143
User Manual 1173.9511.02 ─ 12
Firmware/Software:
V2.1.20
Options:
Multi-carrier support requires R&S CMW-KS881.
Manual operation:
See
CONFigure:EVDO:SIGN<i>:HANDoff:NETWork:PILot:CSECtor
<CarrierSector>
Sets/gets the handoff carrier/sector to which subsequent commands
EVDO:SIGN<i>:HANDoff:NETWork:PILot:AN:ACTive
or
SIGN<i>:HANDoff:NETWork:PILot:AT:ASSigned
apply.
Parameters:
<CarrierSector>
C0S0 | C1S0 | C2S0 | C0S1 | C1S1 | C2S1 | C0S2 | C1S2 |
C2S2 | INACtive
CxSx
: carier/sector selection for handoff
INACtive
: pilot not set (only for pilot 1 or 2)
*RST:
C0S0
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:HANDoff:NETWork:PILot:AN:ACTive
<ActiveOnAN>
Sets/gets the state of a pilot in the handoff destination cell.
The related pilot has to be pre-selected using the
command.
Parameters:
<ActiveOnAN>
OFF | ON
When set to OFF, the related carrier is physically disabled on
the handoff destination cell.
Note that pilot 0 cannot be turned OFF.
*RST:
ON
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:HANDoff:NETWork:PILot:AT:ASSigned
<AssignedToAT>
Sets/gets the assignment state of a pilot in the handoff destination cell. Assigning a
pilot to the AT adds the pilot to the AT's active set in the destination cell.