![Rohde & Schwarz CMW-KE100 User Manual Download Page 546](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807546.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
546
User Manual 1173.9511.02 ─ 12
Min Protocol Revision
Defines the minimum protocol revision (min PRev) which the mobile station has to sup-
port in order that the base station allows a connection setup:
PRev (of the MS) > min PRrev (defined by the BS)
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:SYSTem:MPRevision
4.3.9.2
Base Station Properties
BS information which is sent to the MS so that it can synchronize to the forward
CDMA2000 signal and enter the test mode.
Fig. 4-52: Base Station properties settings
.............................................................................................546
................................................................................................547
PN Offset
Sets the offset index of the PN sequence (PILOT_PN) in units of 64 chips. Changing
the PN offset changes the timing of the pilot channel, the timing and contents of the
sync channel message, and the long code mask of the paging channel.
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:PROPerty:PNOFfset
Call Loss Detect Time
Sets the value of the fade timer to detect when a call is lost or dropped.
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:PROPerty:CLDTime
Page Response Timeout
Sets the timeout value of the page timer (in increments of 1 seconds) to define the
maximum time the R&S
CMW will attempt to page the MS. Setting this timeout to small
values may save time in production tests.
Remote command:
CONFigure:CDMA:SIGN<i>:NETWork:PROPerty:PRTimeout
GUI Reference
深圳德标仪器