![Rohde & Schwarz CMW-KE100 User Manual Download Page 269](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807269.webp)
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
269
User Manual 1173.9511.02 ─ 12
User Margin
Margin that the R&S
CMW adds to the "Expected Nominal Power" in order to deter-
mine its reference power ("Ref. Level"). The "User Margin" is typically used to account
for the known variations of the RF input signal power, e.g. the variations due to a spe-
cific channel configuration.
The appropriate values depend on the configuration of the RL 1xEV-DO signal, e.g. on
the active channels and gain factors. A typical value for the user margin is 9 dB.
Remote command:
CONFigure:EVDO:MEAS<i>:RFSettings:UMARgin
3.3.3 Trigger Settings
The "Trigger" parameters configure the trigger system for both TX measurements: the
1xEV-DO multi evaluation and OLTR measurement.
Fig. 3-21: Multi evaluation configuration: trigger
Trigger Source
Selects the source of the trigger event. Some of the trigger sources require additional
options.
●
Free Run:
The measurement starts immediately after it is initiated. The R&S
CMW decodes
the signal and derives its slot timing. This procedure is repeated after each mea-
surement cycle.
●
IF Power
The measurement is triggered by the power of received signal, converted to an IF
signal. The trigger event coincides with the rising or falling edge of the detected
1xEV-DO power step. This setting can be used to measure short signal bursts
when no continuous 1xEV-DO signal is available (see
The trigger event has to be synchronized to the start of frame. To achieve that, it is
necessary to adjust the
.
●
IF Auto Sync
GUI Reference
135-1095-0799