{<2_SegReliability>
0 | 3 | 4 | 8
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_ACPM10> ...
<12_ACPM1>
<13_ACPCarrier>
<14_ACPP1> ...
<23_ACPP10>
<ACP M/P n> refers to the average channel power at the carrier
frequency minus/plus the frequency offset value number
n
.
Range:
-100 dB to 50 dB
Default unit: dB
<24_MSPowerWide> Results of the wideband (8 MHz) power measurement.
Range:
-55 dBm to 42 dBm
Default unit: dBm
<25_MSPowerNarrow>Results of the narrowband (1.23 MHz) power measurement.
Range:
-55 dBm to 42 dBm
Default unit: dBm
<26_OutOfTolCount> Out of tolerance result, i.e. percentage of measurement intervals
of the statistic count exceeding the specified limits.
Range:
0 % to 100 %
Default unit: %
<27_CurStatCount>} Number of evaluated valid slots in this segment.
Range:
0 to 1000
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.15.20,
V2.0.10: New parameters
<OutOfTolCount>
and
<CurStatCount>
, all
CALCulate:...
commands
V3.0.10: Mnemonic
SPECtrum
replaced by
ACP
, additional
results
SDEviation
and
MINimum
Options:
R&S CMW-KM012
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:ACP:EXTended:AVERage?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:ACP:EXTended:CURRent?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:ACP:EXTended:MAXimum?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:ACP:EXTended:MINimum?
CALCulate:CDMA:MEAS<i>:MEValuation:LIST:ACP:EXTended:SDEViation?
Command Reference
深圳德标仪器
135-1095-0799