<EnableEVM>
OFF | ON
OFF:
Disable measurement.
ON:
Enable measurement of EVM.
*RST:
OFF
<EnableMagError>
OFF | ON
Disable or enable measurement of magnitude error.
*RST:
OFF
<EnablePhaseErr>
OFF | ON
Disable or enable measurement of phase error.
*RST:
OFF
<EnableWaveQual> OFF | ON
Disable or enable measurement of waveform quality.
*RST:
OFF
<EnableIQError>
OFF | ON
Disable or enable measurement of I/Q origin offset and imbal-
ance.
*RST:
OFF
<EnableChPow>
OFF | ON
Disable or enable measurement of channel power.
*RST:
OFF
<EnableChTimeOff> OFF | ON
Disable or enable measurement for channel time offset.
*RST:
OFF
<EnableChPhseOff> OFF | ON
Disable or enable measurement of channel phase.
*RST:
OFF
<EnableWBNBPow> OFF | ON
Disable or enable measurement of wideband and narrowband
power.
*RST:
OFF
<EnableFreqErr>
OFF | ON
Disable or enable measurement of carrier frequency error.
*RST:
OFF
Example:
See
Firmware/Software:
V1.0.15.20,
V1.0.15.23: New parameters
<EnableWBNBPow>
and
<EnableFreqErr>
. Change *RST value of
<StatisticLength>
to 1.