5.4.2.1
Specifying Global Measurement Settings
//*************************************************************************
// System-Reset
//*************************************************************************
SYSTem:RESet 'CDMA Meas1'; *OPC?
*CLS; *OPC?
//*************************************************************************
// Define signal routing and external attenuation
//*************************************************************************
ROUTe:CDMA:MEAS:SCENario:SALone RF1C, RX1
CONFigure:CDMA:MEAS:RFSettings:EATTenuation 2
5.4.2.2
Specifying List Mode Settings
//*************************************************************************
// Define two segments with a length of 20 slots each
// and different analyzer settings.
//*************************************************************************
CONFigure:CDMA:MEAS:MEValuation:LIST:COUNt 2
CONF:CDMA:MEAS:MEV:LIST:SEGMent1:SETup 20,1,833.49E+6,OFF,R36H,R11
CONF:CDMA:MEAS:MEV:LIST:SEGMent2:SETup 20,-10,825.3E+6,ON,R12Q,R11
//*************************************************************************
// Enable modulation results for both segments
// and spectrum results for segment 2 only.
// Select an averaging length of 20 (all measured slots in the segment).
//*************************************************************************
CONF:CDMA:MEAS:MEV:LIST:SEGM1:MODulation 20,ON,ON,ON,ON,ON,ON,ON,ON,ON,ON
CONF:CDMA:MEAS:MEV:LIST:SEGM2:MODulation 20,ON,ON,ON,ON,ON,ON,ON,ON,ON,ON
CONFigure:CDMA:MEAS:MEValuation:LIST:SEGMent2:SPECtrum 20,ON,ON
// *****************************************************************************
// Only for measurements with R&S CMWS:
// Configure the RF input connector per segment.
// *****************************************************************************
CONFigure:CDMA:MEAS:MEValuation:LIST:CMWS:CMODe LIST
CONFigure:CDMA:MEAS:MEValuation:LIST:SEGMent1:CMWS:CONNector R11
CONFigure:CDMA:MEAS:MEValuation:LIST:SEGMent2:CMWS:CONNector R12
//*************************************************************************
// Enable the list mode.
//*************************************************************************
CONFigure:CDMA:MEAS:MEValuation:LIST ON
//*************************************************************************
// Use fast synchronization to the RF input signal and a trigger
// timeout of 1 s. Set retrigger mode.