1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
195
User Manual 1173.9511.02 ─ 12
2.5.9 Network
The following commands define properties of the simulated network and control the
access probe transmission of the AT.
...................................................................................195
2.5.9.1
General Settings
The following commands provide basic network settings.
CONFigure:EVDO:SIGN<i>:NETWork:RELease
<Release>
Selects the network release for the signaling tests.
Parameters:
<Release>
R0 | RA | RB
Release 0, A or B
*RST:
RA
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS881 required for release B
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SID
<SystemID>
Defines the 15-bit System ID that the R&S
CMW broadcasts on its forward 1xEV-DO
signal
Parameters:
<SystemID>
Range:
0 to 32767 (2^15 - 1)
*RST:
1
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
2.5.9.2
Access Network Properties
The following commands define general settings for the simulated access network.
Command Reference
深圳德标仪器