Appendices
A - 104
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
38880000
Safety Communica-
tions Setting Error
Safety process data com-
munications were not estab-
lished with the Safety CPU
Unit because of an incorrect
communications setting.
• The watchdog time was set
incorrectly
• The processing was not
completed within the watch-
dog time because commu-
nications were not
established due to the noise
√
38890000
Safety Frame Error
Safety process data com-
munications were not estab-
lished with the Safety CPU
Unit because an incorrect
frame was received.
• An incorrect frame was
received in safety process
data communications
• There is excessive noise
√
388A0000
Safety Parameter
Error
Safety process data com-
munications were not estab-
lished with the Safety CPU
Unit because an incorrect
parameter was received.
• The set safety slave model
is incorrect
√
388B0000
FSoE Slave Address
Error
Safety process data com-
munications were not estab-
lished with the Safety CPU
Unit because of an incorrect
FSoE slave address.
• The setting of the FSoE
slave address in the safety
process data communica-
tions settings is different
from the setting in the Unit
√
48080000
FPGA WDT Error
An FPGA error was
detected.
• False detection due to a
data read error that was
caused by excessive noise
• Hardware failure
√
64E30000
Drive Prohibition
Input Error
Both the Positive Drive Pro-
hibition (POT) and the Neg-
ative Drive Prohibition Input
(NOT) turned ON.
• An error occurred on the
switch, wire, power supply,
and wiring that were con-
nected to the Positive Drive
Prohibition (POT) or Nega-
tive Drive Prohibition Input
(NOT)
• False detection occurred
because the control signal
power supply was turned
ON slowly
√
68200000
Drive Prohibition
Detected
The operation was stopped
according to the user setting
because the motor ran in
the prohibited direction
when the Drive Prohibition
was enabled.
• Incorrect or broken wiring of
Positive Drive Prohibition
Input (POT) or Negative
Drive Prohibition Input
(NOT)
• Incorrect setting of the Drive
Prohibition Input
√
68210000
Control Right
Release Error
Communications between
the Sysmac Studio and
Servo Drive were inter-
rupted while a specific func-
tion was used from the
Sysmac Studio.
• The USB cable or EtherCAT
cable was disconnected
during the connection with
the Sysmac Studio
• There is excessive noise
• A command sent from the
Sysmac Studio was not
sent to the Servo Drive
because the computer was
in a busy state or the like
√
Event code
(hex)
Event name
Description
Assumed cause
Level
Refer-
ence
Min
Ob
s
In
fo
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...