Appendices
A - 114
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Event name
Regeneration Processing Error
Event code
083F0000 hex
Description
The regeneration processing was stopped to protect the Regeneration Resistor.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling
slave power)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
The regeneration processing is
set inappropriately
Check the regeneration process-
ing setting, and set the same value
as the resistance value of the
Regeneration Resistor in use.
Check the items given for correc-
tions in advance and take counter-
measures as required.
The Regeneration Resistor is
selected inappropriately
Check the operation pattern by the
velocity monitor. Check the load
ratio of Regeneration Resistor, and
perform the following corrections
accordingly.
• Increase the deceleration time
and stopping time.
• Decrease the command velocity
to the motor.
• Use an External Regeneration
Resistor.
• Increase the capacity of the
Servo Drive and the motor.
The Regeneration Resistor is
used for continuous regenera-
tive braking
The Regeneration Resistor can-
not be used for continuous regen-
erative braking.
Do not use the Regeneration
Resistor for continuous regenera-
tive braking.
The applied power supply volt-
age is higher than the specified
value
Apply the specified power supply
voltage.
Review the power supply voltage
to be the specified value before
use.
Regeneration Resistor failure
Check whether the Regeneration
Resistor is faulty, and use one
without failures.
Confirm that the Regeneration
Resistor is not faulty before use.
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: 1802 hex
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 827: ......