A - 115
Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-4 Sys
m
ac Error S
ta
tus C
o
d
es
A
A-4
-2 Err
or De
scriptions
Event name
Overvoltage Error
Event code
08410000 hex
Meaning
The main circuit power supply voltage (P-N voltage) exceeded the operation guarantee range.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling
slave power)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
The P-N voltage exceeded the
specified value
Input the correct voltage.
Input the correct voltage.
The input voltage increased
Use appropriately external devices
such as UPS.
Use appropriately external devices
such as UPS.
The Regeneration Resistor wir-
ing is broken
If a resistance value of the external
resistor is infinite between the ter-
minal B1 and B2 of the Servo
Drive, the wiring is broken.
Replace the external resistor.
Check a resistance value of the
external resistor.
The External Regeneration
Resistor is set or selected inap-
propriately
Confirm the necessary regenera-
tion processing capacity, and con-
nect an appropriate External
Regeneration Resistor. Also, set
the parameters of the External
Regeneration Resistor to the resis-
tance value of the External Regen-
eration Resistor in use.
Select an External Regeneration
Resistor after calculating the nec-
essary regeneration processing
capacity because it varies with
operation patterns or the like. Also,
set the parameter correctly when
using the External Regeneration
Resistor.
Servo Drive failure
If this event occurs again after you
performed all corrections shown
above, replace the Servo Drive.
None
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: 1200 hex
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 827: ......