7 Applied Functions
7 - 18
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
When the software position limit function is enabled in
Software Position Limit - Enable Selection
(3B11-01 hex), if the present position exceeds the specified movement range, the Servo Drive stops the
Servomotor according to the method specified in
Stop Selection
(3B11-02 hex).
The value set in
Enable Selection
(3B11-01 hex) determines the movement range as follows.
Note that the Servomotor does not stop if
Max Position Limit
(3B11-04 hex) is equal to or smaller than
Min Position Limit
(3B11-03 hex).
If the Servomotor stops outside the allowable operating range, commands only for the direction of the
movement range are accepted.
Positive Software Limit (PSOT)
and
Negative Software Limit (NSOT)
of
Function Status
(3000-81 hex)
give the status regardless of the setting in
Enable Selection
(3B11-01 hex).
7-4-3
Description of Operation
Stop Selec-
tion
set value
During deceleration
*1
*1. During deceleration means the period in which the running motor decelerates and its speed reaches 30 r/min
or lower. Once the motor speed reaches 30 r/min or lower and the operation changes to after stopping, the
following operation conforms to the description for the state after stopping, regardless of the motor speed.
After stopping
Deceleration method
Following
error
State after stopping
Following error
2
The deceleration stop torque
is used.
*2
*2. When the deceleration stop torque is used to stop the Servomotor, the operation direction may be reversed if
the inertia is small and the operation speed is slow.
Clear
Lock at the stop position
Cleared at the
stop and held
after stopping
4
*3
*3. If you set
Stop Selection
to
4
, a Software Limit Exceeded (Error No. 34.1) occurs when the movement range
is exceeded.
Stop according to the setting
of Fault reaction option code
---
Stop according to the setting
of Fault reaction option code
---
Min Position
Limit
Max Position
Limit
Positive direction
Negative direction
PSOT
NSOT
Movement range for 0: Positive: Disabled, Negative: Disabled
Movement range for
1: Positive: Disabled, Negative: Enabled
Movement range for
2: Positive: Enabled, Negative: Disabled
Movement range for
3: Positive: Enabled,
Negative: Enabled
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 827: ......