12 - 33
12 Troubleshooting
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
12-
5 T
rou
blesh
oo
ting
12
12-
5-1
T
rou
bleshooting Using Erro
r Disp
lays
B1
00
Command
Warning
A command could not
be executed.
The
Switch on
com-
mand was received.
Send the
Switch on
command with
the main circuit power supply ON.
The
Enable operation
command was received.
Send the
Enable operation
com-
mand under the following condi-
tions.
• In supported operation mode
• The motor rotation speed is 30
r/min or less.
• In the free-run mode, the interpo-
lation time period is the integral
multiple of the communications
cycle.
An operation command
in the prohibition direc-
tion was received after
the immediate stop by
the Drive Prohibition
Input or Software Posi-
tion Limit.
Check status of the Drive Prohibi-
tion Input and Software Position
Limit by the Digital inputs, Sta-
tusword, and Software Position
Limit. Then, do not issue the com-
mand in the drive prohibition direc-
tion.
Homing started.
Set a supported number of the
Homing method for homing.
Start homing at the timing of when
homing is not performed.
The positioning start
command was received
in the Profile position
mode.
Set a supported value for bit 5 and
6 in the Controlword.
B2
00
EtherCAT
Communica-
tions Warning
An EtherCAT communi-
cations error occurred
more than one time.
An EtherCAT communi-
cations cable has a con-
tact failure, or is
connected incorrectly or
broken.
Connect the EtherCAT communica-
tions cable securely. If the cable is
broken, replace it.
Noise
Take noise countermeasures so
that the noise does not affect the
EtherCAT communications cable.
C0
00
STO
Detected
The safety input OFF
state was detected via
the safety input signal or
EtherCAT communica-
tions.
The cable is discon-
nected or broken.
Reconnect the input wiring for
safety inputs 1 and 2. If the cable is
broken, replace it.
The STO input was
turned OFF via Ether-
CAT communications.
Remove the cause that turned OFF
the safety input signal of the Safety
Input Unit.
*1. This error can occur in the unit version 1.1 or later.
*2. Refer to
on page 10-7 for the absolute encoder setup.
*3. Refer to
on page 13-3 for the lifetime of components.
Error No.
Name
Cause
Measures
Main
(hex)
Sub
(hex)
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 827: ......