A - 53
Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A
-2 Co
E Ob
ject
s
A
A-2
-8 Servo Dr
ive Pro
file Object
• This object sets the electronic gear ratio.
• Subindex 01 hex
Motor Revolutions
sets the numerator of the electronic gear. If the set value is
0
,
the encoder resolution is set in the numerator.
• Subindex 02 hex
Shaft Revolutions
sets the denominator of the electronic gear.
• The electronic gear ratio must be between 1/2,000 to 2,000. If it is set outside the range, an Elec-
tronic Gear Setting Error (Error No. 93.00) will occur.
• For details on the electronic gear setting, refer to
• This object selects the homing method in the Homing mode (hm).
z
Description of Set Values
• If the homing operation is started by setting a value other than 8, 12, 19, 20, 33, 34, or 37, a Com-
mand Error (Error No. 91.01) will occur.
• For details on homing, refer to
A-1-5 Homing Mode Specifications
Index
(hex)
Sub-
index
(hex)
Object name
Setting range
Unit
Default
setting
Data
attri-
bute
Size
Access
PDO
map
Com-
plete
access
Modes of
operation
6091
---
Gear ratio
---
---
---
---
---
---
---
Possible
---
00
Number of
entries
---
---
02 hex
---
1 byte
(U8)
RO
---
---
---
01
Motor revolu-
tions
0 to
1,073,741,824
---
1
R
4 bytes
(U32)
RW
---
---
csp, csv,
cst, pp,
pv, hm
02
Shaft revolu-
tions
1 to
1,073,741,824
---
1
R
4 bytes
(U32)
RW
---
---
csp, csv,
cst, pp,
pv, hm
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size
Access
PDO
map
Com-
plete
access
Modes of
operation
6098
---
Homing
method
0 to 37
---
0
E
1 byte
(INT8)
RW
---
Not possi-
ble
hm
Set
value
Description
0
Not specified
8
Homing by Home Proximity Input and home signal (positive
operation start)
12
Homing by Home Proximity Input and home signal (negative
operation start)
19
Homing without home signal (positive operation start)
20
Homing without home signal (negative operation start)
33
Homing with home signal (negative operation start)
34
Homing with home signal (positive operation start)
37
Present home preset
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 827: ......