SD710 Series Servo User Manual Chapter 9 Parameter description
55
situation.
Set value
Instructions
Note
0
Motor runs in CCW (counterclockwise) direction
-
1
The motor runs in CW (clockwise) direction
-
Facing the shaft end, the motor rotates
counterclockwise (CCW)
Facing the shaft end, the motor rotates
clockwise (CW)
Pn277 = 0
Pn277 = 1
Cautions
● When the motor rotation direction (Pn277) is set incorrectly, an abnormal absolute position is
caused,
resulting in an ER.840 fault alarm.
Pn290
Home return mode setting
О
Communication
address: 0x0290
Factory value: 0.100
Setting range: 0x0000~0x23A4
Unit: N/A
Control mode.
□
P
□
S
□
T
!