SD710 Series Servo Drive User's Manual Chapter 7 Auxiliary Functions
41
assist
meri
torious
d
eed
or
service
capab
le
7.26 Encoder over-temperature alarm threshold setting (Fn400)
This auxiliary function is only used to set the Tamagawa encoder.
(1) Pre-implementation recognition matters
●
The parameter disable function (Fn010) is not set to "disable writing".
●
The driver is not enabled.
●
The motor-mounted encoder manufacturer is Tamagawa, i.e. PnF15.X=2, and the encoder model number is
TS5700N8401 or TS5700N8501.
PnF15
☆
Rotary Motor Types & Encoder Manufacturers
●
Address: 0x0F15
Default: 0000
Setting range: 0x0000~0x FFFF
Unit: N/A
Mode.
□
P
□
S
□
T
Encoder manufacturers
0
Do not distinguish manufacturers
1
NK
2
DMC
3
RY
Rotary Motor Type
0
Face Mounted (SPM)
1
Built in (IPM)
Reserved parameters (do not use)
Reserved parameters (do not use)
3rd 2nd 1st 0th
X
Y
Z
W