SD710 Series Servo User Manual Chapter 9 Parameter description
74
Pn604
Input terminal X4 configuration [CN1-8]
О
Communication
address: 0x0604
Factory value: 0x0005
Setting range: 0x0000~0x112F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
Invalid
01
See "Schedule 1 Input Terminal Function Definitions".
...
2F
Input terminal contact properties
0
Normally open
1
Normally closed
Input terminal signal source
0
External hardware terminal X4
1
Internal software status bit given by Pn630.Bit3
Pn605
Input terminal X5 configuration [CN1-33]
О
Communication
address: 0x0605
Factory value: 0x0004
Setting range: 0x0000~0x112F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
Invalid
01
See "Schedule 1 Input Terminal Function Definitions".
...
2F
Input terminal contact properties
0
Normally open
1
Normally closed
Input terminal signal source
0
External hardware terminal X5
1
Internal software status bits given by Pn630.Bit4
3rd 2nd 1st 0th
3rd 2nd 1st 0th
X
Y
Z
W
X
Y
Z
W