![Veichi SD710 Series User Manual Download Page 164](http://html.mh-extra.com/html/veichi/sd710-series/sd710-series_user-manual_860398164.webp)
SD710 Series Servo Drive User's Manual Chapter 7 Auxiliary Functions
20
assist
meri
torious
d
eed
or
service
capab
le
7.14 Motor pole position identification (Fn080)
This auxiliary function is used to enable the identification of the initial motor zero position.
The procedure is shown below.
Steps
Panel display
Keys used
Operations
1
Press the "MODE/SET" key to select the auxiliary function.
Adjust by pressing the "UP" and "DOWN" keys until Fn000
is displayed.
2
Adjust by pressing the "UP" or "DOWN" key until Fn080 is
displayed.
3
Press the "DATA/SHIFT" key for about 1 second and the
pole identification symbol is displayed as shown on the
left.
4
Press the "MODE/SET" key to display the current level for
pole recognition, the initial default value is "40.0" in 0.1%.
5
Press the "UP", "DOWN" and "DATA/SHIFT" keys to
adjust the desired current, which can be adjusted from
20.0% to 120.0%.
6
(blinking)
Press the "MODE/SET" key to start the pole position and
encoder recognition. During the recognition process, the
digital tube is alternately on and off.
Note: During recognition, the current recognition can
be stopped by pressing the "MODE/SET" key.
7
-
After the magnetic pole position recognition is completed,
the display will be as shown on the left and the servo
motor will become OFF.
8
Press the "DATA/SHIFT" key for about 1 second to return
to the Fn080 status.
CAUTION
● The parameter disable function (Fn010) cannot be set to "disable writing".
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
!