![Veichi SD710 Series User Manual Download Page 213](http://html.mh-extra.com/html/veichi/sd710-series/sd710-series_user-manual_860398213.webp)
SD710 Series Servo User Manual Chapter 9 Parameter description
4
Pn006
Function selection basic switch 6
■
Communication Address:
0x0006
Factory
value:
0x1001
Setting range: 0x0000 to 0x4121
Unit: N/A
Control mode.
□
P
□
S
□
T
Overtravel (OT) warning detection option
0
Non-detection of overtravel warnings
1
Detect Overtravel Warning
Reserved parameters (do not change)
Warning detection options
0
Detection warning
1
Non-detection warning (except A.971)
Cooling fan control (for drives with fans)
0
When servo is enabled, fan runs when temperature exceeds 45° C, stops
when it is less than 42° C
The fan stops immediately when the servo is OFF
1
Fan runs immediately when servo is enabled
When the servo is OFF, the fan runs when the temperature exceeds 45° C,
and stops when it is less than 42° C
2
When servo is enabled, the fan runs immediately; when servo is OFF, the
fan stops immediately
3
Forced closure
4
Forced open
Pn007
Stop method in case of drive overtravel (OT)
■
Communication
Address:
0x0007
Factory
value:
0x0001
Setting range: 0x0000~0x0002
Unit: N/A
Control mode.
□
P
□
S
□
T
Used to set how to stop the drive when it generates an overtravel.
Setting
value
Instructions
Note
0
DB stop or free run stop (same stop method as Pn004)
[Model-related]
1
Use the value of Pn053 as the maximum deceleration torque to stop the motor,
then enter servo lock
-
2
Use the value of Pn053 as the maximum deceleration torque to stop the motor,
and then enter the free state
3rd 2nd 1st 0th
X
Y
Z
W