SD710 Series Servo User Manual Chapter 9 Parameter description
116
Default value: type
determination
Set range: 0 to 16384
Unit: N/A
Control mode.
□
P
□
S
□
T
Communica
tion address
Description
Set the hardware current detection factor for .
Note: Do not change the communication address without the manufacturer's permission, as this
may cause irrecoverable damage to the
PnE29
☆
Voltage compensation gain
○
Communication
address: 0x0E29
Default value: 115
Set range: 0 to 300
Units: %.
Control mode.
□
P
□
S
□
T
Communica
tion address
Description
Set the gain value for the compensation voltage value.
PnE2A
☆
Carrier frequency
○
Communication
address: 0x0E2A
Default value: type
determination
Set range: 2000 to 16000
Unit: HZ
Control mode.
□
P
□
S
□
T
Communica
tion address
Description
Setting the carrier (PWM) frequency of the servo