SD710 Series Servo User Manual Chapter 9 Parameter description
110
determined
□
T
PnE10
☆
P-N voltage detection level (the maximum voltage that can be
detected by the hardware)
○
Communication
address
:
0x0E10
Default value: model
determined
Set range
:
0
~
1000
Unit
:
V
Control mode
:
□
P
□
S
□
T
Communica
tion address
Explanation
Set up The calibration value of bus voltage detection. The value is adjusted based on the hardware
part.
For 220V (S2/T2) models, Set up is 500V;
For 380V (T3) models, set up is 940V.
Note: Without the permission of the manufacturer, please do not change the Communication
address yourself, otherwise it may cause irreversible damage to the !
PnE11
☆
P-N voltage detection low-pass filter time constant
○
Communication
address
:
0x0E11
Default
:
0
Set range
:
0
~
10000
Unit
:
us
Control mode
:
□
P
□
S
□
T
PnE12
☆
P-N voltage detection and zero adjustment
○
Communication
address
:
0x0E12
Default
:
Factory
setting
Set range
:
-50
~
50
Unit
:
V
Control mode
:
□
P
□
S
□
T
PnE13
☆
P-N voltage detection gain fine tuning
○
Communication
address
:
0x0E13
Default
:
0
Set range
:
-127
~
127
Unit
:
N/A
Control mode
:
□
P
□
S
□
T
Communica
tion address
Explanation
Set up Set the linearity of bus voltage detection to make relevant adjustments:
:
Note: Without the permission of the manufacturer, please do not change the Communication
address by yourself, otherwise it may cause irreversible damage to the
!
PnE14
☆
Main circuit detection filter selection switch
■
Communication