SD710 Series Servo Drive User's Manual Chapter 8 Monitoring Parameters
10
8.7 Clearable monitoring function code
This drive supports a function where some of the monitoring function codes can be
cleared for practical use.
Clear method: Press "UP" + "DOWN" keys on the keyboard panel at the same time.
Clearable monitoring function codes.
Un number
Show Description
Un006
Input command pulse counter
Un007
Motor encoder feedback pulse counter 1
Un008
Motor encoder feedback pulse counter 2
Un017
Encoder Z signal output number
Un018
Encoder Z signal one-way output number
s
8.8 Detailed description of some monitoring function codes
Un00B
Regenerative load factor (value at 100% of the
regenerative power that can be processed, showing
the regenerative power consumption for a 10s cycle)
Unit: 1%
Communication
address:
0xE00B
Parameter
Description
This function code is used to record the accumulated value of heat generated by regenerative
braking after the servo drive's main loop voltage is greater than the regenerative braking threshold,
and it only records the current regenerative load rate for the last 10S clocks.
Note:
The regenerative load accumulation value monitored by the monitoring function code Un143
is the accumulation value for the entire process (including heat accumulation and heat dissipation).
Data/
MODE/SET
Data/