SD710 Series Servo User Manual Chapter 9 Parameter description
70
9.6 Auxiliary parameters (Pn5xx)
Pn500
Jogging speed (JOG)
О
Communication
address: 0x0500
Factory value: 200
Setting range: 0 ~ 2000
Unit: rpm
Control mode.
□
P
□
S
□
T
Pn502
Program JOG operation method
О
Communication
address: 0x0502
Factory value: 0x0000
Setting range: 0x0000~0x0005
Unit: N/A
Control mode.
□
P
□
S
□
T
Program JOG operation method
0
(Waiting time Pn535 → forward movement
Pn531) × number of moves Pn536
1
(Waiting time Pn535 → reverse movement Pn531) × number of moves Pn536
2
(Waiting time Pn535 → forward movement Pn531) × number of moves Pn536
(Waiting time Pn535 → reverse movement Pn531) × number of moves Pn536
3
(Waiting time Pn535 → reverse movement Pn531) × number of moves Pn536
(Waiting time Pn535 →forward movement Pn531) × number of moves Pn536
4
(Waiting time Pn535→ forward movement Pn531→
(Waiting time Pn535 → reverse movement Pn531) × number of moves Pn536
5
(Waiting time Pn535→ reverse movement Pn531→
(Waiting time Pn535 → forward movement Pn531) × number of moves Pn536
Reserved parameters (please do not change)
Reserved parameters (please do not change)
Reserved parameters (please do not change)
Cautions
Pn502.X=0, 2, 4, when the panel operation is enabled, it needs to press the "UP" key to start the PJOG.
Pn502.X=1, 3, 5, when the panel operation is enabled, it needs to press the "Down" key to start the
PJOG.
!
3rd 2nd 1st 0th
X
Y
Z
W