![Veichi SD710 Series User Manual Download Page 390](http://html.mh-extra.com/html/veichi/sd710-series/sd710-series_user-manual_860398390.webp)
SD710 Series Servo Drive User Manal Chapter 11 Communication
35
1A01h
-
TPDO4 Mapping Parameters
REC
-
-
-
0
h
Number of valid mappings for
TPDO2
-
Uint8
RW
N
1
h
TPDO2 Mapping Object 1
-
Uint32
RW
N
2
h
TPDO2 Mapping Object 2
-
Uint32
RW
N
3
h
TPDO2 Mapping Object 3
-
Uint32
RW
N
4
h
TPDO2 mapping object 4
-
Uint32
RW
N
1A02h
-
TPDO3 Mapping Parameters
REC
-
-
-
0
h
Number of valid mappings for
TPDO3
-
Uint8
RW
N
1
h
TPDO3 Mapping Object 1
-
Uint32
RW
N
2
h
TPDO3 Mapping Object 2
-
Uint32
RW
N
3
h
TPDO3 Mapping Object 3
-
Uint32
RW
N
4
h
TPDO3 mapping object 4
-
Uint32
RW
N
1A03h
-
TPDO4 Mapping Parameters
REC
-
-
-
0
h
Number of valid mappings for
TPDO4
-
Uint8
RW
N
1
h
TPDO4 Mapping Object 1
-
Uint32
RW
N
2
h
TPDO4 Mapping Object 2
-
Uint32
RW
N
3
h
TPDO4 Mapping Object 3
-
Uint32
RW
N
4
h
TPDO4 Mapping Object 4
-
Uint32
RW
N
11.2.8.3 List of 6000h cluster objects
The Canopen6000h group object dictionary assignment is shown in the following table.
Index
Sub
index
Name
Access
rights
Mapping
option
Data
type
Unit
Range
Default
6039
00
error code
RO
Y
UINT16
-
UINT16
-
6040
00
control word
RW
Y
UINT16
-
UINT16
0
6041
00
status word
RO
Y
UINT16
-
UINT16
-
6060
00
operating mode
RW
Y
UINT8
-
UINT8
0
6061
00
Operation mode
display
RO
Y
UINT8
-
UINT8
-
6062
00
Position command
value
RO
Y
INT32
command
unit
INT32
-
6064
00
Actual position
value
RO
Y
INT32
command
unit
INT32
-
6065
00
Position Deviation
Excess Threshold
RW
Y
UINT32
command
unit
UINT32
3840000
6067
00
Position reaches
threshold
RW
Y
UINT32
command
unit
UINT32
100
6068
00
Position arrival time
RW
Y
UINT16
ms
UINT16
0
606B
00
Speed command
value
RO
Y
INT16
0.1rpm
INT16
-