SD710 Series Servo Drive User Manual Chapter 4 Panel Operation
9
4.6 Method of Setting Parameter (Pn□□□□□)
4.6.1 Settings Below 5-digit
(1) Positive Number Setting with a Setting Range of Less than 5 Digits
The following describes the setting method when changing the setting value of the speed loop integral (Pn102) from 40.0
to 120.0.
Steps
Panel display
Buttons used
Operations
1
Press the MODE/SET key to enter the parameter setting
status. If the function code parameter number is not
displayed as "Pn102", adjust it by pressing UP or DOWN
until "Pn102" is displayed.
2
Press the DATA/SHIFT key for about 1 second to display
the current setting value of "Pn100".
3
Press the DATA/SHIFT key to move the blinking digit to
make the number "4" blink. (The number of blinking digits
can be changed)
4
Press the UP key 8 times to adjust the setting to 120.0
5
(blinking)
When the MODE/SET button is pressed, "donE" will flash
and the set value will change from 40.0 to 120.0.
6
-
When the set value is valid, the screen as shown on the
left is displayed.
7
Press the DATA/SHIFT key for about 1 second to return to
the "Pn102" display.
(2) Negative Number Setting with a Setting Range of Less than 5 Digits
The following describes how to set the internal speed command 0 (Pn304) when the setting value is changed from 100
to -800.
Steps
Panel display
Buttons used
Operations
1
Press the MODE/SET key to enter the parameter setting
status. If the function code parameter number is not
displayed as "Pn304", adjust it by pressing UP or DOWN
until "Pn304" is displayed.
2
Press the DATA/SHIFT key for about 1 second to display
the current setting value of "Pn304".
3
Press the DATA/SHIFT key to move the blinking digit to
make the number "1" blink. (The number of blinking digits
can be changed)
4
Press the DOWN key 9 times to adjust the setting to -800.
5
(blinking)
When the MODE/SET button is pressed, "donE" will flash
and the setting value will change from 100 to -800.
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/