SD710 Series Servo User Manual Chapter 9 Parameter description
71
Pn503
Program JOG movement distance
О
Communication
address: 0x0503
★
Factory value: 60,000
Setting range: 1 ~ 1073741824
Unit: instruction unit
Control mode.
□
P
□
S
□
T
Pn505
Program JOG acceleration and deceleration time
О
Communication
address: 0x0505
Factory value: 100
Setting range: 2 ~ 10000
Unit: ms
Control mode.
□
P
□
S
□
T
Pn506
Program JOG waiting time
О
Communication
address: 0x0506
Factory value: 100
Setting range: 0
~
10000
Unit: ms
Control mode.
□
P
□
S
□
T
Pn507
Number of program JOG movement
О
Communication
address: 0x0507
Factory value: 1
Setting range: 0~1000
Unit: times
Control mode.
□
P
□
S
□
T
Parameter
Description
Used to set the number of cycle periods during program JOG.
Cautions
● When Pn502 is set to 2 or 3 while Pn507 is set to 0, the program JOG function is disabled.
● When Pn507 = 0, there is no limit to the number of program JOG
movement.
Pn508
Program JOG movement speed
О
Communication
address: 0x0508
Factory value: 500
Setting range: 1 ~ 10000
Unit: rpm
Control mode.
□
P
□
S
□
T
!