SD710 Series Servo Drive User's Manual Chapter 7 Auxiliary Functions
40
assist
meri
torious
d
eed
or
service
capab
le
Default: 200
Setting range: 0
~
10000
Unit: 1rpm
Mode:
□
P
□
S
□
T
(3) Operation steps
The basic setup procedure is shown below.
Steps
Panel display
Keys used
Operations
1
Press MODE/SET to select the auxiliary function. Adjust
by pressing UP or DOWN until Fn000 is displayed.
2
Adjust by pressing UP or DOWN until Fn305 is
displayed.
3
Press the DATA/SHIFT key for about 1 second, then the
display will be as shown on the left.
Note: The Pn500 is used as the reference point for initial
entry.
4
Adjust the desired tap speed by pressing UP, DOWN
and DATA/SHIFT.
Note:
The maximum speed value is 1200rpm.
5
Press the MODE/SET key, then the display will be as
shown on the left, and enter the positive limit point
setting status.
Adjust the corresponding load to the positive limit point
with the "UP" or "DOWN" key.
6
Press the MODE/SET key to set the current positive limit
point. Also enter the negative limit point state.
Adjust the corresponding load to the positive limit point
with the "UP" or "DOWN" key.
7
Press the MODE/SET key to set the current negative
limit point. Also exit the corresponding limit point setting
state.
8
Press the DATA/SHIFT key for about 1 second to return
to the Fn305 display.
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/