SD710 Series Servo Drive User's Manual Chapter 12 Motion Control
4
H
L
-H
-L
H
L
L
-L
Home position switch signal
Forward limit signal
The deceleration point signal is OFF while
starting the home position return. The forward
limit is not touched while home position return.
The deceleration point signal is OFF while
starting the home position return. The forward
limit is touched while home position return.
The deceleration point signal is ON while
starting the home position return.
Motor Z signal
Home position return method 3:
-H
-L
-H
L
-L
H
L
L
-L
Home position switch signal
Forward limit signal
The deceleration point signal is OFF while
starting the home position return. The forward
limit is not touched while home position return.
The deceleration point signal is OFF while
starting the home position return. The forward
limit is touched while home position return.
The deceleration point signal is ON while
starting the home position return.
Motor Z signal
Home position return method 4:
H
-L
-L
Forward limit signal
The deceleration point signal is OFF
while starting the home position return.
The deceleration point signal is ON
while starting the home position return.
Home position return method 5: