![Veichi SD710 Series User Manual Download Page 188](http://html.mh-extra.com/html/veichi/sd710-series/sd710-series_user-manual_860398188.webp)
SD710 Series Servo Drive User's Manual Chapter 7 Auxiliary Functions
44
assist
meri
torious
d
eed
or
service
capab
le
displayed. To set the detection result, you must proceed to
step 9.
(Note)
Even if the detection ends normally, if the running time
exceeds 2 seconds, the detection accuracy may not be
sufficient, and the detection accuracy may be improved if
the command amplitude is increased to slightly more than
"15" and then executed again. However, if the command
amplitude is increased, the vibration and noise generated
by the machine will become larger in a short period of
time. When changing the command amplitude, gradually
increase the amplitude value and observe the situation
while making the change.
9
Press "MODE/SET" to automatically set the resonant
frequency for detection. When the notch filter is set
normally, "donE" flashes and the display returns to the left.
After the 1st band notch filter frequency has been set, the
2nd band notch filter frequency (Pn156) is automatically
set in Pn150.X = 1.
Press the "MODE/SET" key once more to return to step 5.
(Note)
The notch filter frequency cannot be set in Pn150.X and
Pn150.Z if the band 1 and band 2 notch filter frequencies
have already been set.
Not using the notch filter frequency detected by this
function is to set Pn150.X = 0 (notch filter is invalid).
10
Press the "DATA/SHIFT" key for about 1 second to exit.
MODE/SET
Data/
MODE/SET
Data/