SD710 Series Servo Drive User's Manual Chapter 12 Motion Control
5
H
-L
-L
Reverse limit signal
The deceleration point signal is OFF
while starting the home position return.
The deceleration point signal is ON
while starting the home position return.
Home position return method 6:
H
-L
-L
Forward limit signal
The deceleration point signal is OFF
while starting the home position return.
The deceleration point signal is ON
while starting the home position return.
Motor Z signal
Home position return method 7:
-H
L
L
Reverse limit signal
The deceleration point signal is OFF
while starting the home position return.
The deceleration point signal is ON
while starting the home position return.
Motor Z signal