![Veichi SD710 Series User Manual Download Page 208](http://html.mh-extra.com/html/veichi/sd710-series/sd710-series_user-manual_860398208.webp)
SD710 Series Servo Drive User's Manual Chapter 8 Monitoring Parameters
18
Parameter
Description
This function is used to monitor the current message activation status of CanOpen.
CanOpen running state 1
Bit0
SDO telegrams (0: off; 1: active)
Bit1
PDO telegrams (0: off; 1: active)
Bit2
Consumer heartbeat (0: off; 1: active)
Bit3
Producer heartbeat (0: off; 1: active)
CanOpen running state 2
Bit4
Emergency telegrams (0: off; 1: active)
Bit5
Synchronized frames (0: off; 1: active)
Bit6
Reserved
Bit7
Reserved
Reserved
Reserved
Un142
Regenerative load accumulation value
Unit:
0.1%
Communication
address:
0xE00A
Parameter
Description
This function code is used to record that the servo drive has accumulated the
regenerative load and the accumulated value is the heat generated and dissipated
during the whole process.
The drive generates an ER.920 warning when the monitored value of the Un142 is
greater than 50.0%.
The drive generates an ER.320 fault when the monitored value of the Un142 is
greater than 100.0%.
Note:
Regenerative braking is turned off after a regenerative overload fault is
generated.