SD710 Series Servo User Manual Chapter 9 Parameter description
43
In position mode, the type of pulse used to set the drive.
Setting
value
Instructions
Note
0
Pulse + Direction
-
1
Forward and Reverse Pulse Columns
(CW+CCW)
-
2 to 3
Reserved
4
90° phase difference quadrature pulse AB (4x
frequency)
-
Pn202
External pulse command logic
■
Communication
address: 0x0202
Factory value: 0x0020
Setting range: 0x0000~0x0001
Unit: N/A
Control mode
.
□
P
External pulse command logic
0
Positive logic (original direction)
1
Negative logic (reverse)
Reserved parameters (please do not change)
Reserved parameters (please do not change)
Reserved parameters (please do not change)
Pn203
External pulse command multiplier
○
Communication address:
0x0203
Factory value: 1
Setting range: 1 to 100
Unit: x 1
Control mode.
□
P
Parameter
Description
Used to process the corresponding multiplier for external pulse commands, which can be
switched via the digital input terminal X (P-GAIN). It can be switched to 1x to any set N times
(max. 100 times).
Note
: This multiplier is only valid for external pulse commands, not for internal program JOG,
Smart Adjust, etc.
Pn204
Electron gear numerator (N)
○
Communication
address: 0x0204
★
3
rd
2nd 1st 0th
X
Y
Z
W