SD710 Series Servo Drive User's Manual Chapter 8 Monitoring Parameters
11
Un00E
Total drive power-up time
Unit: 0.1s
Communication
address:
0xE00E
Parameter
Description
This function code is used to record the total time that the servo drive has been running after the
main circuit voltage has been established. The function code is 32 bits and the panel display is
decimal data.
Caution
●
When multiple successive power-ups and power-downs of the drive occur in a short period of time,
there may be a maximum of 1 hour deviation in the total power-up time record.
● The drive total power
-up time timing starts when the drive main circuit voltage is established.
Un017
Encoder Z signal output number
Unit: -
Communication
Address:
0xE017
Parameter
Description
This function code is used to record the number of servo drive encoder Z signal outputs. The
recording method is absolute number (actual number of outputs).
Note
:
Auto-zero when re-powered or press the "UP" + "DOWN" keys on the keypad at the same
time to clear.
Un018
Encoder Z signal one-way output
number
Unit: -
Communication
Address:
0xE018
Parameter
Description
This function code is used to record the number of servo drive encoder Z signal outputs. The
recording method is relative number (associated with direction).
Caution
●
Auto-zero when re-powered or press the "UP" + "DOWN" keys on the keypad at the same time to
clear.
●
The Z signal is only counted cumulatively by the function code Pn074.X = 1.
Un02A
Internal signal status 1
Unit: N/A
Communication
address:
0xE02A
!
!