SD710 Series Servo Drive User Manual Chapter 5 Commissioning and Operation
17
Command pulse input frequency
doubli ng switching input signal
/PSEL
/PSELA
Valid
Invali d
Below 4ms
x1
Pn203
x1
Internal
operation
Command pulse input frequency
doubling switching input signal
Valid
Invalid
Below 4ms
Figure 5.16 Input-output timing diagram requirements for command pulse input multiplier switching
“
The
”command pulse input multiplier
signal is a universal configurable switch input, see
for wiring details.
Note
●
When the input pulse frequency is too low and the Pn203 setting is too large, unstable speed
may occur.
●
Switch the command pulse multiplier when the position command pulse is 0. If you switch when
the position command pulse is not 0, the servo motor may cause position deviation or position loss.
5.2.4 Pulse Input Form
Table 5-7 Descriptions related to the form of pulse input
!
Pn202.X
setting
Pn201
setting
Command
form
Forward command
Reversal command
0
0
Pulse +
Direction
PULS
SIGN
PULS
SIGN
0
1
CW+CCW
CW
CCW
CW
CCW
0
4
Orthogonal
coding 4x
A Phase
90°
B Phase
A Phase
B Phase
90°
1
0
Pulse +
Direction
PULS
SIGN
PULS
SIGN