SD710 Series Servo User Manual Chapter 9 Parameter description
77
Pn612
Output terminal Y2 configuration [CN1-4/5]
О
Communication
address: 0x0612
Factory value: 0x0002
Setting range: 0x0000~0x110F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
See "Schedule 2 Output Terminal Function Definitions".
...
0F
Output terminal contact properties
0
Normally open
1
Normally closed
Output terminal signal source
0
Function Code Pn610 Distribution Signal Control
1
Function code Pn631.Bit1 bit control
Pn613
Output terminal Y3 configuration [CN1-2/3]
О
Communication
address: 0x0613
Factory value: 0x0007
Setting range: 0x0000~0x110F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
See "Schedule 2 Output Terminal Function Definitions".
...
0F
Output terminal contact properties
0
Normally open
1
Normally closed
Output terminal signal source
0
Function code Pn613 Distribution signal control
1
Function code Pn631.Bit2 bit control
3rd 2nd 1st 0th
X
Y
Z
W
3rd 2nd 1st 0th
X
Y
Z
W