SD710 Series Servo Drive User Manual Chapter 3 Wiring and Installation
35
(2) Separate the noise filter ground wire from its output power line
L1
L2
L3
Noise
filter
AC
L1
L2
L3
Noise
filter
AC
(3) The noise filter should be grounded separately using a short thick wire as possible, do not share a ground wire with
other grounded equipment.
Noise
filter
AC
Servo
drive
Servo
drive
L1
L2
L3
Shielding grounding
Noise
filter
AC
Servo
drive
Servo
drive
L1
L2
L3
Shielding grounding
(4)
Installation and control cabinet noise filter ground processing method:
When the noise filter and servo drive
installed in the same control cabinet, it is recommended to fix the filter and servo drive on the same metal plate to ensure
that the contact part is conductive and well lapped, and ground the metal plate.
Noise
filter
AC
L1
L2
L3
Servo
drive
Servo
drive
Shielding grounding
Grounding
Figure 3.21 Schematic of noise filter ground handling
3.7 Precautions for the Use of the Cable.
(1) Do not bend the cable or put it under tension. The core diameter of the signal cable is only 0.2mm or 0.3mm, so it is
easy to break.
(2) When the cable is to be moved, please use a flexible cable, as ordinary cable is easily damaged after a long period