SD710 Series Servo User Manual Chapter 9 Parameter description
48
Parameter
Description
In the case of fixed point start/stop, the gear gap compensation value shows an exponential
relationship with time, which is used to determine the rate of convergence of this compensation
curve.
Pn232
Low frequency vibration detection sensitivity (relative to
positioning completion signal threshold)
О
Communication
address: 0x0232
Factory value: 40.0
Setting range: 0.1 to 300.0
Unit: %
Control mode.
□
P
Parameter
Description
Set the threshold value for low frequency vibration detection, vibration detection value = Pn232 x Pn262.
the smaller the setting, the easier it is to detect vibration.
Pn233
Low frequency vibration suppression 1 frequency A
О
Communication
address: 0x0233
Factory value: 50.0
Setting range: 1.0 ~ 250.0
Unit: Hz
Control mode.
□
P
Pn234
Low Frequency Vibration Suppression 1 Frequency B
О
Communication
address: 0x0234
Factory value: 70.0
Setting range: 1.0 ~ 250.0
Unit: Hz
Control mode.
□
P
Pn235
Low Frequency Vibration Suppression 2 Frequency
О
Communication
address: 0x0235
Factory value: 200.0
Setting range: 1.0 ~ 200.0
Unit: Hz
Control mode.
□
P
Parameter
Description
Used to set the suppression center frequency for low frequency vibration. This function is turned on
when this function code is not 200.0Hz.
When this function is turned on, the response of the drive will be decreased.
After the model tracking function is turned on (Pn240.X=1), this function can be turned on by function
code Pn240.Y=2.
Gear gap compensation value
Time
The larger the time, the slower the convergence