SD710 Series Servo User Manual Chapter 9 Parameter description
85
Pn756
Weak magnetic control loop proportional gain
О
Correspondence to:
0x0756
Factory value: 30
Setting range: 10 ~ 1000
Unit: Hz
Control mode.
□
P
□
S
□
T
Pn757
Integration time constants for weak magnetic control loops
О
Communication
address: 0x0757
Factory value: 16
Setting range: 10 ~ 1000
Unit: us
Control mode.
□
P
□
S
□
T
Pn758
Weak magnetic control loop integral upper limit value
О
Communication
address: 0x0758
Factory value: 100
Setting range: 0 ~ 200
Unit: %
Control mode.
□
P
□
S
□
T
Pn759
Weak magnetic control voltage threshold
О
Communication
address: 0x0759
Factory value: 115
Setting range: 50 ~ 150
Unit: %
Control mode.
□
P
□
S
□
T
Pn75A
Maximum weak magnetic current during weak magnetic control
О
Communication
address: 0x075A
Factory value: 95
Setting range: 50 ~ 150
Unit: %
Control mode.
□
P
□
S
□
T
Pn75B
Main circuit voltage filtering time during weak magnetic control
О
Communication
address: 0x075B
Factory value: 2.0
Setting range: 1.0 ~ 10.0
Unit: ms
Control mode.
□
P
□
S
□
T
Parameter
Description
The sliding average filtering times for the DC voltages used for the weak magnetic calculations were
subjected to the associated averaging process.
Pn77F
External input power failure detection function switch
О
Communication