SD710 Series Servo Drive User Manual Chapter 5 Commissioning and Operation
33
Fn. NO
Parameter
Range
Default
Unit
Pn415
Internal speed limit value for
torque control
0 to 10,000
0
rpm
5.4.3 Torque single trigger
As shown in the figure below, when the drive receives the external start trigger signal, it first enters into the locking
process, in which the drive is subject to two restrictions, one is the maximum torque limit, and the other is the maximum
speed limit, when not accelerated to the maximum speed, the drive outputs at the set maximum torque, when the speed
reaches the maximum value, the torque limit is carried out, and as the load gradually increases and is influenced by the
resistance, the The motor speed gradually decreases, when the motor speed is low enough and lasts for a preset
duration, this action ends and waits for the next start trigger signal.
Related input terminals
Value
Symbolic
Function
Instructions
Trigger
Mode
0x14
T-CTRG
Torque
command
trigger
(a) In the case of torque control, this signal is used to
select the desired torque command.
The corresponding trigger edge signal is configured via
the function code Pn430.
high and low
levels
trig along
□
T
Configure the torque command trigger terminal (0x14) inside the function codes Pn601 to Pn609, and then control the
single trigger function of torque according to the trigger method set by Pn430.
Figure 5.28 Schematic diagram of single torque trigger
Related function codes
Fn. NO
Parameter
Range
Default
Unit
Pn400.X
Torque mode command source
4: External single trigger given
0
-
Pn410
Internal torque command 1
-500.0 to 500.0
0
%
Pn415
Internal speed limit value during torque
control
0 to 10,000
100
rpm