SD710 Series Servo User Manual Chapter 9 Parameter description
75
Pn606
Input terminal X6 configuration [CN1-32]
О
Communication
address: 0x0606
Factory value: 0x0006
Setting range: 0x0000~0x112F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
Invalid
01
See "Schedule 1 Input Terminal Function Definitions".
...
2F
Input terminal contact properties
0
Normally open
1
Normally closed
Input terminal signal source
0
External hardware terminal X6
1
Internal software status bit given by Pn630.Bit5
Pn607
Input terminal X7 configuration [CN1-12]
О
Communication
address: 0x0607
Factory value: 0x0007
Setting range: 0x0000 ~ 0x112F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
Invalid
01
See "Schedule 1 Input Terminal Function Definitions".
...
2F
Input terminal contact properties
0
Normally open
1
Normally closed
Input terminal signal source
0
External hardware terminal X7
1
Internal software status bits given by Pn630.Bit6
3rd 2nd 1st 0th
3rd 2nd 1st 0th
X
Y
Z
W
X
Y
Z
W