2 General 

information 

The structure of these operating instructions is based on 
the service life phases of the electrical drive (subsequently 
referred to as product). 

The manufacturer reserves the right to make changes to the 
technical data included in these operating instructions. The-
se may deviate from the respective model of the product 
while the factual information are generally not changed and 
are not losing their validity. The current state-of-the-art can 
be obtained from the manufacturer at all times. Potential 
claims cannot be asserted. Deviations from text and pictori-
al statements are not possible and depending on the tech-
nical development, setup and accessories of the product. 
Deviating information on special models are included by the 
manufacturer in the sales documentation. Other information 
shall remain unaffected by this. 

Table of contents

Operating and installation 
instructions  

1

General information  

1

2.1 

Standards and guidelines  

2

2.2 

Intended use  

2

2.3 

Foreseeable misuse  

2

2.4 

Warranty and liability  

2

2.5 

Customer service of the manufacturer  

2

3 Safety 

 

2

3.1 

General safety instructions  

2

3.2 

Layout of safety instructions  

2

3.3 

General safety principles  

3

3.4 

General obligations of the operator  

3

3.5 

General requirements on personnel  

3

3.6 

Safety instructions on technical condition  

4

3.7 

Safety instructions on transport, 
assembly and installation  

4

3.8 

Safety instructions on operation  

4

3.9 

Safety instructions on electrical installation  

4

Product description  

4

5 Installation 

 

5

5.1 

Mechanical mounting  

5

5.2 

Electrical connection  

6

5.3 

Connection example, RolTop-915 120 V / 60 Hz  

6

5.4 

Parallel connection  

6

5.5 Commissioning 

 

6

5.5.1  Installation cable connection  

6

5.5.2  Wireless connection (transmitter operation)  

7

5.6 

End position and relief settings  

7

5.6.1  Relief function for end position(s)  

7

5.6.2  Relief function at the upper stop  

7

5.6.3  Relief function at the lower stop  

7

5.6.4  Changing / deleting of end positions 

and deleting the relief function  

7

5.6.5  Programming or deleting additional 

fabric positions  

7

5.6.6  Four options for end position settings  

7

5.6.7  Option A: Upper and lower end position 

freely con

fi

 gurable  

8

5.6.8 Option 

B: 

Fixed upper end position, 
lower end position freely con

fi

 gurable  

8

5.6.9 Option 

C: 

Fixed upper and lower end position  

8

5.6.10  Option D:  Upper end position freely con

fi

 gurable, 

fi

 xed lower end position  

8

5.7 

Transmitter programming  

9

5.8 

Programming additional transmitters(s)  

9

5.9 

Technical data  

9

6 Troubleshooting 

 

9

7 Servicing 

 

9

8 Cleaning 

 

9

9 Repair 

 

10

10 Address 

 

10

11 

Disposal / scrapping  

10

12 

EC Declaration of Conformity  

10

13 

US: Addendum to the manual 
UL approval  

10

14 

CA: Addendum au manuel 
Homologation UL  

10

Summary of Contents for RolTop-915

Page 1: ... misuse 2 2 4 Warranty and liability 2 2 5 Customer service of the manufacturer 2 3 Safety 2 3 1 General safety instructions 2 3 2 Layout of safety instructions 2 3 3 General safety principles 3 3 4 General obligations of the operator 3 3 5 General requirements on personnel 3 3 6 Safety instructions on technical condition 4 3 7 Safety instructions on transport assembly and installation 4 3 8 Safet...

Page 2: ...t from the safety instructions in these operating instructions applicable local regulations on pre vention of accidents environmental protection and occupa tional safety must be observed Regulations and standards for safety assessment can be found in the EC Declaration of Conformity 2 2 Intended use This product is intended for use in facade construction for driving electrical sun protection devic...

Page 3: ... in the country of operation and other binding regulations on ope rational safety prevention of accidents and environmental protection are complied with All work on the product must only performed by trained safety related instructed and authorized personnel Appropriately qualified personnel must observe all appli cable standards and regulations in the country of installation and inform the custom...

Page 4: ... Product description 3 6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition The operator is obliged to only operate the product in technically flawless and operationally safe condition The technical condition must comply with statutory require ments applicable at the date of manufacturing stated on the name plate If dangers ...

Page 5: ...iately after removing the Rol Top 915 from its original packaging The drive system must be installed in a position safe from rain Important On delivery factory settings the RolTop 915 is in commis sioning mode It is necessary to set the end positions refer to section 5 6 Optimum use of the wireless signal Position the antenna as freely as possible and reposition it in case of bad reception Do not ...

Page 6: ... initial commissioning check the correct connec tion of the PE conductor NOTE Damage to the RolTop 915 due to incorrect electrical con nection Before initial commissioning check the correct connec tion of the PE conductor Damage to or destruction of the RolTop 915 due to ingress of humidity For devices with protection class IP44 the customer provided connection of cables or plugs wiring must also ...

Page 7: ...n D refer to section 5 6 9 Activating the relief function at the lower limit stop 1 In a medium fabric position using the installation cable or a programmed transmitter keep the DOWN button pressed from step section 5 6 8 and 5 6 9 and press additionally simultaneously the UPbutton Keep both buttons pressed until the fabric stops The relief function at the lower limit stop is activated 5 6 4 Chang...

Page 8: ...omatically The lower end position is set Optional Activation of the relief function for the lower limit stop refer to section 5 6 3 End position setting of option D is completed Fig 12 End position setting option D 8 US CA elero GmbH End position settings 5 6 7 Option A Upper and lower end position freely configurable Option A Upper and lower end position freely configurable In a medium fabric pos...

Page 9: ...ric stops briefly moves on stops and moves downwards 5 On the additionally transmitter to be program med immediately max 1 second after start of a down movement press the DOWNbutton The status indicator flashes briefly The drive system stops Programming of the additional transmitter is complete Stopping the bidirectional wireless programming mode Press the STOP button for at least 6 seconds until ...

Page 10: ...en Produktbezeichnung Rohrmotor RolTop S 915 120V 60Hz alle Varianten RolTop M 915 120V 60Hz alle Varianten Beschreibung Einsteckantrieb für Rollläden mit 915 MHz Funkempfänger Die Übereinstimmung der s bezeichneten Produkte s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen berücksichtigt R TTE Richtlinie 1999 5 EG Niederspannungsrichtlinie 2006 95 E...