CDC-TW-0502-1-ACB

 

instructions

Please order bracket sets separately

Summary of Contents for CDC-TW-0502-0500-1-ACB

Page 1: ...CDC TW 0502 1 ACB instructions Please order bracket sets separately ...

Page 2: ...f pressure on window gasket after closing Direct connection of additional closing edge protection at the drive possible SKS option WARNING Read all safety warnings instructions illustrations and specifications provided with this product Failure to follow all instructions listed below may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Obs...

Page 3: ... 30 S6 EN 60034 1 Aluminium powdercoated RAL 9006 IP 32 5 75 C 30 min 300 C 90 not condensing LpA 35 dB A Closing edge protection activated 3 repetitions of stroke Locking relief activated retraction lift max 0 2 mm Closing edge protection In the CLOSE direction the drive has an active protection for the main closing edge If there is an overload in the closing ranges C3 and C2 the drive runs OPEN ...

Page 4: ...n with perfect position directly from the control panel In this process all status messages such as the OPEN and CLOSED signals opening stroke and drive errors are transmitted to the control panel Functional description Wiring Is the drive wired properly See connection plans Diagnostics with SCS software The SCS software and a BSY interface is required for further troubleshooting or configuration ...

Page 5: ...22949Ammersbek Dirk Dingfelder Maik Schmees Member of the Board Authorized signatory Technical Director 21 02 2017 Maintenance and cleaning Maintenance work is only allowed when the device is in a de energized condition Inspection and maintenance has to be carried out according to D H maintenance notes Only original D H spare parts may be used RepairistobecarriedoutexclusivelybyD H Wipe away debri...

Page 6: ... WH 24 V DC 24 V DC 1 2 3 4 5 L 6 N 7 Z A E X a b LT Gruppe Mot a Mot b MOT BK BK OG 2x47kW En dm od ul Te rm ina l mo du le Mo du le ter mi na l EM 47 K WH BN OG YE GN GY Mot a Mot b ACB a HS BSY a BSY b ACB b CDC TW 0502 1 Junction box Monitoring SHEV fast running Normal mode ...

Page 7: ...itoring Cable according to D H table for layout of cables See instructions for use of control panel 1 2 3 4 5 L 6 N 7 Z A E X a b LT Group Mot a Mot b MOT BK BK OG 2x47kW En dm od ul Te rm ina l mo du le Mo du le ter mi na l EM 47 K WH BN OG YE GN GY Mot a Mot b ACB a HS BSY a BSY b ACB b CDC TW 0502 1 Junction box Monitoring Connection FRA 11 BSY VLD 51 BSY VP FRA 11 BSY VLD 51 BSY Mot a Mot b BS...

Page 8: ...a BN Mot b OG ACB a HS GY ACB b GN BSY b YE BSY a WH Mot a Option Opción SKS BN Mot b OG SKS GY SKS GN BSY b YE BSY a WH Mot a BN Mot b OG ACB a HS GY ACB b GN BSY b YE BSY a WH Mot a Connection PinAssignment Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 161 491 4840 E Mail enquiry dyerenvironmental co uk www dyerenvironmental co uk ...