Varispeed E7

CIMR-E7Z

Varispeed E7

Frequency inverter for pumps and fans

• Energy saving function.
• Advanced PID controller with dedicated HVAC 

functions.

• 12 pulse operation for harmonics reduction.
• Speed search.
• Standard RS-485 communication - MODBUS.
• Optional network cards 

(DeviceNet, PROFIBUS, CANOpen, LONWORKS).

• CE, UL, and cUL marked and Germanischer Lloyds 

approval.

• Embedded OMRON PLC functionality with 

PLC option card

• PC configuration tool CX-drive.
• CE, UL, and cUL marked and Lloyds approval.

E7IP54

• Robust metal chassis.
• LCD operator.
• Built in RFI filter.

Customized software

• The inverter software can be customized to meet 

specific application. Examples:

• Pump sequencer (S-8801).

*For detailed information please refer to CASE software section.

 Ratings

• 200 V Class 0.4 to 110 kW.
• 400 V Class 0.4 to 300 kW.

System configuration

C22

R52

C24

PE

C16

U11

U8

R6

C26

C28

JP3

U

6

U

7

T

1

U9

+

+

R15

R15

R25

R15

R20

R30

R7

R5

C5

R21

U14

C17

R14

R28

R

R11

JP

1

C1
U10

C3

R

5

R

1

R

2

R

3

6

R3

C

2

1

R

3

5

R70

R120

R75

R78

R114

C

2

2

+

+

U1

+

C35

R99

U12

R

95

R39

R40

R57

R56

D6

R6

U15

R54

R55

R8

T

R

2 11 R

1

1

R

1

1

0

R107

R

1

1

3

TR

1

C13

U13

C10

SI-N

COD

E No

.

U17

7360

0-C0

210

JP5

JP6

RT4

R

10
R

10

R

10

5

R10

2

C12

C11

R94

R97

R96

C20

R95

C

39

R13

1

Y1

U

10

C

33

Communication card

PLC option card

3G3IV-PCN329-E
Inverter to PC cable

3G3IV-PCN126/326
Digital operator
extension cable

JVOP-161-OY
Digital operator
(LED display)

JVOP-160 OY
Digital operator
(LCD display)

CX-Drive

Line filter

LKEB_ braking
resistor unit

CDBR_B
braking unit

Braking accessories

Varispeed E7

* E7 IP54 types are built-in filter inverters.

see note

Y203-EN2-02-Katalog.book  Seite 309  Mittwoch, 24. Mai 2006  2:22 14

Summary of Contents for Varispeed E7

Page 1: ...ed information please refer to CASE software section Ratings 200 V Class 0 4 to 110 kW 400 V Class 0 4 to 300 kW System configuration C22 R52 C24 PE C16 U11 U8 R6 C26 C28 JP3 U6 U7 T1 U9 R15 R15 R25 R15 R20 R30 R7 R5 C5 R21 U14 C17 R14 R28 R R11 JP1 C1 U10 C3 R5 R1 R2 R36 R3 C21 R35 R70 R120 R75 R78 R114 C2 2 U1 C35 R99 U12 R95 R39 R40 R57 R56 D6 R6 U15 R54 R55 R8 TR2 11 R11 R11 0 R10 7 R11 3 TR1 ...

Page 2: ... 4220 4300 IP54 model CIMR E7Z 47P52 40112 40152 40182 40222 40302 40372 40452 40552 Max applicable motor output1 1 Standard 4 pole motors are used for max applicable motor output Choose the inverter model whose rated current is allowable within the motor rated current range 2 A 3 wire transformer is required on the power supply for 12 phase rectification To agg 400 V class Kw 0 55 0 75 1 5 2 2 3 ...

Page 3: ...d lower limits for frequency references DC braking for starting and stopping high slip braking PI control with sleep function energy saving control MEMOBUS communications RS 485 422 19 2 kbps maximum fault reset and copy function Protective functions Motor protection Protection by electronic thermal overload relay Instantaneous overcurrent protection Stops at approx 200 of rated output current Fus...

Page 4: ...5 2055 0 450 725 348 325 700 86 75 2075 0 87 90 2090 0 500 850 358 370 820 15 4 5 M12 108 110 2110 0 575 885 378 445 855 140 150 400 V class 3 phase 0 4 Not available please use the IP20 type removing the upper and lower cover 0 75 1 5 2 2 4 0 5 5 7 5 11 15 18 5 22 4022 0 3 275 450 258 220 435 7 5 100 2 3 M6 21 Fan cooled 30 4030 0 37 4037 0 325 550 283 260 535 105 36 45 4045 0 55 4055 0 75 4075 0...

Page 5: ... 94 75 2075 1 95 400 V class 3 phase 0 4 40P4 1 1 140 280 157 126 280 266 7 39 5 M5 3 Self cooled 0 75 40P7 1 1 5 41P5 1 2 2 42P2 1 177 59 4 Fan cooled 3 7 43P7 1 4 0 44P0 1 5 5 45P5 1 7 5 47P5 1 2 200 300 197 186 300 285 8 65 5 2 3 M6 6 11 4011 1 15 4015 1 240 350 207 216 350 335 7 5 78 10 18 5 4018 1 22 4022 1 3 275 535 258 220 450 435 85 100 24 30 4030 1 37 4037 1 325 715 283 260 550 535 105 40...

Page 6: ...427 15 40152 260 30 536 18 5 40182 662 22 40222 410 650 300 370 620 12 2 5 M10 43 754 30 40302 989 37 40372 580 750 330 410 714 11 2 5 M14 71 1145 45 40452 1317 55 40552 1701 Part name Qty Cable gland for input 1 Cable gland for motor output 1 Cable gland for control 1 Cable gland for fieldbus 1 Door key 1 Blind plug control cable entry 1 Blind plug fieldbus cable entry 1 W W1 H H1 H2 t1 D 4 d Dig...

Page 7: ... M5 25 186 285 M6 3G3RV PFI3060 SE 408 236 65 355 390 205 6 5 M6 32 5 216 335 M6 3G3RV PFI3410 SE 1 1 Flat filters are not possible to be mounted as footprint filters 386 115 260 306 240 235 12 0 M12 3G3RV PFI3600 SE 1 386 135 260 306 240 235 12 0 M12 3G3RV PFI3800 SE 1 564 160 300 516 420 275 9 0 M12 Model Dimensions A B C D E F G H 200 V 3G3RV PFI2130 SE 366 180 90 280 310 65 6 5 M10 3G3RV PFI21...

Page 8: ...l LKEB _ Dimensions in mm Weight kg A B C D MTG screw 220 V class 20P7 105 275 50 260 M5 x 3 3 0 21P5 130 350 75 335 M5 x 4 4 5 22P2 130 350 75 335 M5 x 4 4 5 23P7 130 350 75 335 M5 x 4 5 0 25P5 250 350 200 335 M6 x 4 7 5 25P5 250 350 200 335 M6 x 4 8 5 400 V class 40P7 105 275 50 260 M5 x 3 3 0 41P5 130 350 75 335 M5 x 4 4 5 42P2 130 350 75 335 M5 x 4 4 5 43P7 130 350 75 335 M5 x 4 5 0 45P5 250 3...

Page 9: ... 2 5 Dia holes 4 d Tap a a a a b b W3 W3 W2 W2 W1 W a a 4 d Tap H2 H3 H2 H3 H1 H B A W3 W3 W2 W2 a a W1 W a a 4 d Tap 59 H3 19 H3 H1 H B A W3 W3 W2 W2 a a Fig 1 Model CIMR E7Z Draw ing Dimensions in mm W H W1 W2 W3 H1 H2 H3 A B d 20P4 1 155 302 126 6 8 5 290 9 5 6 138 271 M5 20P7 21P5 22P2 23P7 25P5 27P5 210 330 180 8 5 6 5 316 9 7 197 298 M6 2011 2015 250 392 216 8 5 372 9 5 10 233 353 2018 2022 ...

Page 10: ...ncy reference 0 to 10 V 20 kΩ Analog input power supply 15 V 20 mA Multi function analog input 1 Default Frequency Bias 4 to 20 mA 250 Ω Analog input power supply 15 V 20 mA Terminating resistance MEMOBUS communication RS 485 422 Shielded wires Twisted pair shielded wires Multi function analog output 1 0 to 10 V 2 mA Default Output frequency 0 to 10 V Multi function analog output 2 0 to 10 V 2 mA ...

Page 11: ...ted standard DC power supply 1 2 1 Braking unit 3 DC reactor 1 2 DC power supply1 1 DC power supply 1 2 1 Braking unit 3 1 2 3 l2 Cooling fan power supply2 2 Cooling fan power supply r l1 l2 200 to 220 VAC 50 Hz 200 to 230 VAC 60 Hz A transformer is required for 230 V 50 Hz or 240 V 50 60 Hz power supply r l1 Cooling fan power supply3 3 Cooling fan power supply r l1 200 l2 200 200 to 220 VAC 50 Hz...

Page 12: ...09 4 to 20 mA 250 Ω 0 V to 10 V 20 kΩ 0 to 20 mA 250 Ω AC Analog reference common E G Shield wire optional ground line connection point Digital output signals M1 Running signal 1NO contact Operating when ON Multi function contact outputs Relay contacts contact capacity 1 A max at 250 VAC 1 A max at 30 VDC 3 M2 M3 Zero speed Zero level b2 01 or below when ON M4 MA Fault output signal Fault when CLO...

Page 13: ... 1 4 1 6 2 8 4 0 5 8 6 0 9 5 13 18 24 30 34 46 57 69 85 110 140 160 200 230 280 390 510 Rated current A 1 8 2 1 3 7 5 3 7 6 8 0 12 5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 506 675 Heat loss W Fin W 14 17 36 59 80 91 127 193 252 326 426 466 678 784 901 120 139 161 209 238 279 323 374 583 Inside unit W 39 41 48 56 68 70 82 114 158 172 208 259 317 360 415 495 575 671 853 100 114 137 153 ...

Page 14: ... 0 24 45 240 0 044 45 120 0 18 55 280 0 038 55 150 0 15 75 360 0 026 75 200 0 11 90 500 0 02 90 110 250 0 09 110 500 0 02 132 160 330 0 06 185 490 0 04 220 300 660 0 03 Varispeed E7 Level detector Braking resistor unit Braking resistor unit 3 Braking unit 2 2 Braking unit 1 Braking resistor overload Relay trip contact thermal relay trip contact Cooling fin overheat contact thermoswitch contact Coo...

Page 15: ... 10 12 25 20P7 240 10 12 25 21P5 240 15 23 55 22P2 240 20 34 98 23P7 240 30 82 220 25P5 240 40 220 610 27P5 240 60 290 1300 2011 240 80 450 5000 2015 240 100 1200 7200 2018 240 130 1800 7200 2022 240 150 870 16200 2030 240 180 1500 23000 2037 240 240 2100 19000 2045 240 300 2700 55000 2055 240 350 4000 55000 2075 240 450 7100 64000 2090 240 550 11000 64000 2110 240 600 13000 83000 Inverter type FU...

Page 16: ... CIMR E7Z20P71 1 5 Kw 7 0 A CIMR E7Z21P51 2 2 Kw 9 6 A CIMR E7Z22P21 3 7 Kw 15 A CIMR E7Z23P71 5 5 Kw 23 A CIMR E7Z25P51 7 5 Kw 31 A CIMR E7Z27P51 11 Kw 45 A CIMR E7Z20111 15 Kw 58 A CIMR E7Z20151 18 5 Kw 71 A CIMR E7Z20181 IP00 22 Kw 85 A CIMR E7Z20220 30 Kw 115 A CIMR E7Z20300 37 Kw 145 A CIMR E7Z20370 45 Kw 180 A CIMR E7Z20450 55 Kw 215 A CIMR E7Z20550 75 Kw 283 A CIMR E7Z20750 90 Kw 345 A CIMR...

Page 17: ... PFI2160 SE A 100 m 160 6 0 CIMR E7Z2045 3G3RV PFI2200 SE A 100 m 200 11 0 CIMR E7Z2055 CIMR E7Z2075 3G3RV PFI3410 SE A 100 m 400 8 6 CIMR E7Z2090 CIMR E7Z2110 3G3RV PFI3600 SE A 100 m 600 11 0 Inverter model Line filters Varispeed E7 Model EN 55011 class Current A Weight kg CIMR E7Z40P4 3G3RV PFI3010 SE B 25 m A 100 m 10 1 2 CIMR E7Z40P7 CIMR E7Z41P5 CIMR E7Z42P2 CIMR E7Z43P7 3G3RV PFI3018 SE B 2...

Page 18: ...verter setting or referencing parameters and monitoring output current watt hours or similar items through LONWORKS communications with peripheral devices Type Model Description Function PLC option cards 3G3RV P10CDT E 3G3 P10CDT E DRT PLC option Full features wireless installation and seamless access to the inverter parameters and ana logue digital inputs and outputs Embedded Compobus S fieldbus ...

Page 19: ... 27P5 780 W 20 Ω 1 125 9 6 11 2011 2011 2400 W 13 6 Ω 1 125 9 6 15 2015 2015 3000 W 10 Ω 1 125 9 6 18 5 2018 2022B 1 2015 3000 W 10 Ω 1 125 9 6 22 2022 2022 4800 W 6 8 Ω 1 125 6 4 30 2030 2015B 2 2015 3000 W 10 Ω 2 125 9 6 37 2037 2015B 2 2015 3000 W 10 Ω 2 100 9 6 45 2045 2022B 2 2022 4800 W 6 8 Ω 2 120 6 4 55 2055 2022B 2 2022 4800 W 6 8 Ω 2 100 6 4 75 2075 2110B 1 2022 4800 W 6 8 Ω 3 110 1 6 90...

Page 20: ...st of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No I21E EN 02 ...