2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
90
List Manual, 09/2017, A5E33842890
Description:
Sets the minimum delay time between two data transfers of the absolute value for an SSI encoder.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description:
Sets the configuration for an SSI encoder.
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For bit 06:
The quiescent signal level of the data line corresponds to the inverted, set level.
Description:
Sets the configuration of the Sensor Module.
Notice:
A bit-wise configuration is only possible if the corresponding property is also present in r0458.
p0428[0...n]
Encoder SSI monoflop time / Enc SSI t_monoflop
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 [µs]
65535 [µs]
30 [µs]
p0429[0...n]
Encoder SSI configuration / Enc SSI config
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-
-
0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Transfer code
Binary code
Gray code
-
02
Transfer absolute value twice
Yes
No
-
06
Data line during the monoflop time
High level
Low level
-
p0430[0...n]
Sensor Module configuration / SM config
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-
-
1110 0000 0000 1000 0000 0000 0000
0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
17
Burst oversampling
Yes
No
-
18
Continuous oversampling (reserved)
Yes
No
-
19
Safety position actual value sensing
Yes
No
-
20
Speed calculation mode (only SMC30)
Incremental diff
Flank time meas
-
21
Zero mark tolerance
Yes
No
-
22
Rotor position adaptation
Yes
No
-
23
De-select commutation with zero mark
Yes
No
-
24
Commutation with selected zero mark
Yes
No
-
25
Switch off encoder voltage supply during
parking
Yes
No
-
27
Extrapolate position values
Yes
No
-
28
Cubic correction
Yes
No
-
29
Phase correction
Yes
No
-
30
Amplitude correction
Yes
No
-
31
Offset correction
Yes
No
-