2 Parameters
2.2 List of parameters
SINAMICS G120 CU250S-2 Control Units
606
List Manual, 09/2017, A5E33842890
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Fail-safe Digital Input
SLS: Safely Limited Speed
Description:
Sets the fail-safe digital input (F-DI) for the "SDI positive" function.
Value:
0:
Static selected
1:
F-DI 0
2:
F-DI 1
3:
F-DI 2
255:
Static deselected
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Fail-safe Digital Input
SDI: Safe Direction (safe motion direction)
Description:
Sets the fail-safe digital input (F-DI) for the "SDI negative" function.
Value:
0:
Static selected
1:
F-DI 0
2:
F-DI 1
3:
F-DI 2
255:
Static deselected
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Fail-safe Digital Input
SDI: Safe Direction (safe motion direction)
p10130
SI Motion SDI positive input terminal (processor 2) / SI SDI pos F-DI P2
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0
p10131
SI Motion SDI negative input terminal (processor 2) / SI SDI neg F-DI P2
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 255
0